Package | nictiz.fhir.nl.stu3.zib2015 |
Type | StructureDefinition |
Id | Id |
FHIR Version | R3 |
Source | https://simplifier.net/resolve?scope=nictiz.fhir.nl.stu3.zib2015@1.0.0&canonical=http://nictiz.nl/fhir/StructureDefinition/bodyweight |
Url | http://nictiz.nl/fhir/StructureDefinition/bodyweight |
Version | 1.0 |
Status | retired |
Date | 2016-03-25 |
Name | Vital Signs Profile |
Title | VitalSigns BodyWeight |
Experimental | False |
Realm | nl |
Description | FHIR Body Weight Profile - Copied FHIR Vital Sign Profile to remove .component.value quantity type constrain. More informatino can be found in GForge ticket #13796 or in the FHIR zulip chat https://chat.fhir.org/#narrow/stream/implementers/subject/Vital.20signs.20supporting.20observations. |
Copyright | CC0 |
Type | Observation |
Kind | resource |
No resources found
StructureDefinition | |
http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns ![]() | VitalSigns |
Note: links and images are rebased to the (stated) source
{
"resourceType" : "StructureDefinition",
"id" : "bodyweight",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">to do</div>"
},
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-summary",
"valueMarkdown" : "####Complete Summary of the Mandatory Requirements\r\r1. One code in `Observation.code` which must have\r - a fixed `Observation.code.coding.system`=**'http ://loinc.org'**\r - a fixed `Observation.code.coding.code`= **'29463-7'**\r - Other additional codes are allowed - e.g. more specific LOINC\r Codes, SNOMED CT concepts, system specific codes. All codes\r SHALL have an system value\r2. `Observation.valueQuantity.code` = **'kg', 'g', or '[lb_av]'**"
}
],
"url" : "http://nictiz.nl/fhir/StructureDefinition/bodyweight",
"version" : "1.0",
"name" : "Vital Signs Profile",
"title" : "VitalSigns BodyWeight",
"status" : "retired",
"experimental" : false,
"date" : "2016-03-25",
"publisher" : "Health Level Seven International (Orders and Observations Workgroup)",
"contact" : [
{
"name" : "Nictiz",
"telecom" : [
{
"system" : "email",
"value" : "info@nictiz.nl",
"use" : "work"
}
]
}
],
"description" : "FHIR Body Weight Profile - Copied FHIR Vital Sign Profile to remove .component.value quantity type constrain. More informatino can be found in GForge ticket #13796 or in the FHIR zulip chat https://chat.fhir.org/#narrow/stream/implementers/subject/Vital.20signs.20supporting.20observations.",
"copyright" : "CC0",
"fhirVersion" : "3.0.1",
"mapping" : [
{
"identity" : "workflow",
"uri" : "http://hl7.org/fhir/workflow",
"name" : "Workflow Mapping"
},
{
"identity" : "sct-concept",
"uri" : "http://snomed.info/conceptdomain",
"name" : "SNOMED CT Concept Domain Binding"
},
{
"identity" : "v2",
"uri" : "http://hl7.org/v2",
"name" : "HL7 v2 Mapping"
},
{
"identity" : "rim",
"uri" : "http://hl7.org/v3",
"name" : "RIM Mapping"
},
{
"identity" : "w5",
"uri" : "http://hl7.org/fhir/w5",
"name" : "W5 Mapping"
},
{
"identity" : "sct-attr",
"uri" : "http://snomed.info/sct",
"name" : "SNOMED CT Attribute Binding"
}
],
"kind" : "resource",
"abstract" : false,
"type" : "Observation",
"baseDefinition" : "http://nictiz.nl/fhir/StructureDefinition/zib-VitalSigns",
"derivation" : "constraint",
"differential" : {
"element" : [
{
"id" : "Observation",
"path" : "Observation",
"short" : "FHIR Body Weight Profile",
"definition" : "This profile defines how to represent body weight observations in FHIR using a standard LOINC code and UCUM units of measure.",
"alias" : [
"FHIR Lichaamsgewicht-profiel"
]
},
{
"id" : "Observation.code",
"path" : "Observation.code",
"short" : "Body Weight",
"definition" : "Body Weight.",
"comment" : "additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.",
"alias" : [
"Lichaamsgewicht"
]
},
{
"id" : "Observation.code.coding",
"path" : "Observation.code.coding",
"slicing" : {
"discriminator" : [
{
"type" : "value",
"path" : "code"
}
],
"ordered" : false,
"rules" : "open"
}
},
{
"id" : "Observation.code.coding:bodyweightcode",
"path" : "Observation.code.coding",
"sliceName" : "BodyWeightCode"
},
{
"id" : "Observation.code.coding:bodyweightcode.system",
"path" : "Observation.code.coding.system",
"type" : [
{
"code" : "uri"
}
],
"fixedUri" : "http://loinc.org"
},
{
"id" : "Observation.code.coding:bodyweightcode.code",
"path" : "Observation.code.coding.code",
"type" : [
{
"code" : "code"
}
],
"fixedCode" : "29463-7"
},
{
"id" : "Observation.valueQuantity",
"path" : "Observation.valueQuantity"
},
{
"id" : "Observation.valueQuantity.code",
"path" : "Observation.valueQuantity.code",
"binding" : {
"extension" : [
{
"url" : "http://hl7.org/fhir/StructureDefinition/elementdefinition-bindingName",
"valueString" : "BodyWeightUnits"
}
],
"strength" : "required",
"description" : "Common UCUM units for Body Weight",
"valueSetReference" : {
"reference" : "http://hl7.org/fhir/ValueSet/ucum-bodyweight"
}
}
}
]
}
}